Standard Mode Operation - EJ Internal Memory Full and Nearly-Full Conditions
When the Electronic Journal is programmed for Standard mode operation and it reaches the nearly-full condition or full
condition, a message is displayed and a warning beep can be programmed to sound at the beginning and/or end of
each transaction. When the nearly-full condition is signalled, there are less than 700 lines free in memory, for the full
condition there are less than 300. The operator display indicates the number of lines left.
For the nearly-full condition, you can continue with the transaction by pressing one of these keys:
to continue with the transaction, recording it in the journal
to continue with the transaction but not recording it in the journal.
For the full condition, the transaction in course cannot be recorded in the journal.
Press either or to continue with the transaction.
You can then either print the contents of the electronic journal (as explained for EJ Reports in “Reports Common to X
and Z Modes”), or you can continue with other transactions ignoring the full/nearly-full condition. Remember, however,
that in the case of the full condition, further transaction data will NOT be stored in journal and the consecutive receipt
counter will not increase.
NOTE: To know how many lines are left in the Electronic Journal, in Registration mode outside of a sales
transaction, press .
FUNCTION KEY SETUP
You can program various parameters that affect how these function keys operate:
CASH, CHECK, CHARGE, CREDIT1, CREDIT2, CREDIT3, CREDIT4, CREDIT5, CREDIT6
PO/RA
#/NS
Select Programming Mode -> Configuration setup -> Function key setup. Navigate to the field you want to personalize
and enter its data (see “Data Entry Mode” for the keys to use). At the end, you can press to return to the Main
menu or to return to the previous menu.
Menu Item Possible Values
Description
EJ System STNDARD,
DYNAMIC,
ON SD
Set operation mode for EJ:
STNDARD - Standard Mode - data is registered sequentially with memory
nearly-full condition signaled (an indicator appears at bottom left of
display). See below for further details.
DYNAMIC - Dynamic Mode - data is registered cyclically in memory,
starting again from the first line when memory is full. No memory full
condition is signaled.
ON SD - On Storage Device - the electronic journal data in the buffer is
automatically saved on the SD memory card until the card is full.
EJ Store SALES,
ALL TRN
Type of transaction data to store in EJ: SALES - store only sales
transactions recorded in Registration and Manager modes, ALL TRN -
store all transactions registered on the system.
Beep at Beginning YES, NO For full or nearly-full conditions, enable Beep at beginning of transaction.
YES - Enable, NO - Disable.
Beep at End YES, NO For full or nearly-full conditions, enable beep at end of transaction.
YES - Enable, NO - Disable.

Table of Contents

Other manuals for Olivetti ECR 7900

Related product manuals