OMNI 4000/7000 Operations and Maintenance Guide – Rev F
a. Select Products in the Configure
tree in the left panel.
b. Expand the item to see the entire list
of products.
a. Select a product in the tree to display its configuration options in the screens on
the right.
b. In the Product tab, enter a name or identifier (up to 32 character ASCII string) for the
product in the Name group.
c. Enter a numeric identifier in the Numeric Name group, as needed.
Select the Density Correction Factor
(DCF) to use when running this product.
For liquid applications, there are up
to 32 configurable products. You do
not have to use or configure all of
them.
If a Meter Run or Station has
been set up for density/gravity,
the DCF A and B values can be
found and/or adjusted at
Configure tree > Meter
Run/Station (#) item >
Density options > Setup tab.