A-11
Appendices
EtherCAT Communication Unit USER’S MANUAL (3G3AX-MX2-ECT)
A-4 Inverter Parameter List
App
3000
hex
45
hex
0044 hex Fault Monitor 6
Cause
d086 RO Refer to Inverter fault factor list on
page A-12.
Possible
(TxPDO)
3000
hex
46
hex
0045 hex Fault Monitor 6
Inverter Status
Refer to Inverter fault factor list on
page A-12.
Possible
(TxPDO)
4000
hex
47
hex
0046 hex Fault Monitor 6
Frequency
0 to 100000 0.01 [Hz] Possible
(TxPDO)
3000
hex
49
hex
0048 hex Fault Monitor 6
Current
Output current value at the time of
tripping
0.01 [A] Possible
(TxPDO)
3000
hex
4A
hex
0049 hex Fault Monitor 6 Voltage DC input voltage at the time of
tripping
0.1 [V] Possible
(TxPDO)
4000
hex
4B
hex
004A
hex
Fault Monitor 6
RUN Time
Total RUN time at the time of
tripping
1 [h] Possible
(TxPDO)
4000
hex
4D
hex
004C
hex
Fault Monitor 6
ON Time
Power ON time at the time of
tripping
1 [h] Possible
(TxPDO)
3000
hex
4F
hex
004E
hex
Warning Monitor d090 RO Warning code Possible
(TxPDO)
3009
hex
13
hex
0900 hex EEPROM Write WO 0: Motor parameter recalculation
1: Set value storage in EEPROM
Other: Motor parameter recalculation
and EEPROM
Not
possible
3009
hex
15
hex
0902 hex EEPROM Write Mode
Selection
WO 0: Write disabled
1: Write enabled
Not
possible
Index
Sub-
index
Register
No.
Function name
Parameter
No.
R/W Monitor and setting items
Data
resolution
PDO
map