RX Quick Start Guide 29
PROGRAMMING RX
3.15 Analogue outputs
Several monitors are available through the analogue outputs [AM], [AMI] or the PWM output [FM].
When inverter is in sensor vector control the real motor speed from encoder (d008) is used instead of the output frequency.
For the pulse train output there are two types of outputs, code “03” and “08” outputs a pulse train with a 50% duty cycle while the
PWM has a fixed frequency of 156.25Hz were the duty cycle is changed depending on the output.
When the monitor displays the value set in digital current monitor reference (C030), 1440Hz is output.
C130 Output 11 ON delay 0.0 to 100.0 s
C131 Output 11 OFF delay
C132 Output 12 ON delay 0.0 to 100.0 s
C133 Output 12 OFF delay
C134 Output 13 ON delay 0.0 to 100.0 s
C135 Output 13 OFF delay
C136 Output 14 ON delay 0.0 to 100.0 s
C137 Output 14 OFF delay
C138 Output 15 ON delay 0.0 to 100.0 s
C139 Output 15 OFF delay
C140 Relay output on delay 0.0 to 100.0 s
C141 Relay output off delay
d006 Multi-function output monitor
Parameter Parameter name Description
C027 FM selection 00: Output FQ (Output frequency)
01: OI (Output current)
02: Output TRQ (Output torque)
03: Pulse FQ (Digital output frequency)
04: Output V (Output voltage)
05: Power
06: Thermal (Thermal load rate)
07: LAD-FQ (LAD frequency)
08: Pulse I (Digital current monitor)
09: Motor tmp (Motor temperature)
10: Heat sink tmp (Fin temperature)
12: YA0 (Drive programming)
19: OP1 (Option board 1)
20: OP2 (Option board 2)
C028 AM selection 00: Output FQ (Output frequency)
01: OI (Output current)
02: Output TRQ (Output torque)
04: Output V (Output voltage)
05: Power
06: Thermal (Thermal load rate)
07: LAD-FQ (LAD frequency)
08: Pulse I (Digital current monitor)
09: Motor tmp (Motor temperature)
10: Heat sink tmp (Fin temperature)
11: Out TRQ sign (Output torque <signed>)
13: YA1 (Drive programming)
19: OP1 (Option board 1)
20: OP2 (Option board 2)
C029 AMI selection 00: Output FQ (Output frequency)
01: OI (Output current)
02: Output TRQ (Output torque)
04: Output V (Output voltage)
05: Power
06: Thermal (Thermal load rate)
07: LAD-FQ (LAD frequency)
09: Motor tmp (Motor temperature)
10: Heat sink tmp (Fin temperature)
14: YA2 (Drive programming)
C030 Digital current monitor reference
value
Current with digital current monitor output at 1,440Hz
0.20 x Rated current to 2.00 x Rated current
Parameter Parameter name Description