A032 Multi-step speed reference 12 0.00/starting frequency to max frequency Hz 122Eh 0.00
122Fh
A033 Multi-step speed reference 13 0.00/starting frequency to max frequency Hz 1230h 0.00
1231h
A034 Multi-step speed reference 14 0.00/starting frequency to max frequency Hz 1232h 0.00
1233h
A035 Multi-step speed reference 15 0.00/starting frequency to max frequency Hz 1234h 0.00
1235h
A038 Jogging frequency 0.00/starting frequency to 9.99 Hz 1238h 6.00
A039 Jogging stop selection 00: FRS (Free running on jogging stop/disabled in opera-
tion)
01: DEC (Deceleration stop on jogging stop/disabled in
operation)
02: DB (DC injection braking on jogging stop/disabled in
operation)
03: FRS (RUN) (Free running on jogging stop/enabled in
operation)
04: DEC (RUN) (Deceleration stop on jogging stop/
enabled in operation)
05: DB (RUN) (DC injection braking on jogging stop/
enabled in operation)
- 1239h 04
A041 Torque boost selection 00: Manual torque boost
01: Automatic torque boost
123Bh 00
A241 2nd torque boost selection 00: Manual torque boost
01: Automatic torque boost
223Bh 00
A042 Manual torque boost voltage 0.0 to 20.0 % 123Ch 1.0
A242 2nd manual torque boost voltage 0.0 to 20.0 %
223Ch 1.0
A342 3rd manual torque boost voltage 0.0 to 20.0 %
323Ch 1.0
A043 Manual torque boost frequency 0.0 to 50.0 % 123Dh 5.0
A243 2nd manual torque boost frequency 0.0 to 50.0 %
223Dh 5.0
A343 3rd manual torque boost frequency 0.0 to 50.0 %
323Dh 5.0
A044 V/F characteristics selection 00: VC (Constant torque characteristics)
01: VP (Special reduced torque characteristics)
02: Free V/F (characteristics)
03: SLV (Sensorless vector control)
04: 0SLV (0-Hz sensorless vector control)
05: V2 (Sensor vector control)
123Eh 00
A244 2nd V/F characteristics selection 00: VC (Constant torque characteristics)
01: VP (Special reduced torque characteristics)
02: Free V/F (characteristics)
03: SLV (Sensorless vector control)
04: 0SLV (0-Hz sensorless vector control)
05: V2 (Sensor vector control)
223Eh 00
A344 3rd V/F characteristics selection 00: VC (Constant torque characteristics)
01: VP (Special reduced torque characteristics)
323Eh 00
A045 Output voltage gain 20 to 100 % 123Fh 100
A046 Automatic torque boost voltage compensation gain 0 to 255 1240h 100
A246 2nd automatic torque boost voltage compensation
gain
0 to 255
2240h 100
A047 Automatic torque boost slip compensation gain 0 to 255 1241h 100
A247 2nd automatic torque boost slip compensation gain 0 to 255
2241h 100
A051 DC injection braking selection 00: OFF (Disabled)
01: ON (Enabled)
02: ON (FQ) (Frequency control [A052 set value])
1245h 01
A052 DC injection braking frequency 0.00 to 400.00 Hz 1246h 0.50
A053 DC injection braking delay time 0.0 to 5.0 s 1247h 0.0
A054 DC injection braking power 0 to 100 (0.4 to 55 kW) % 1248h 50
0 to 80 (75 to 132 kW) 40
A055 DC injection braking time 0.0 to 60.0 s 1249h 0.5
A056 DC injection braking method selection 00: Edge operation
01: Level operation
124Ah 01
A057 Startup DC injection braking power 0 to 100 (0.4 to 55 kW)
0 to 80 (75 to 132 kW)
% 124Bh 0
A058 Startup DC injection braking time 0.0 to 60.0 s 124Ch 0.0
A059 DC injection braking carrier frequency 0.5 to 15.0 (0.4 to 55 kW) kHz 124Dh 5.0
0.5 to 10.0 (75 to 132 kW) 3.0
A061 Frequency upper limit 0.00/frequency lower limit to max frequency Hz 124Fh 0.00
1250h
A261 2nd frequency upper limit 0.00/2nd frequency lower limit to 2nd max frequency Hz
224Fh 0.00
2250h
A062 Frequency lower limit 0.00/starting frequency to frequency upper limit Hz 1251h 0.00
1252h
A262 2nd frequency lower limit 0.00/starting frequency to 2nd frequency upper limit Hz
2251h 0.00
2252h
A063 Jump frequency 1 0.0 to 400.0 Hz 1253h 0.00
1254h
A064 Jump frequency width 1 0.0 to 10.00 Hz 1255h 0.50
A065 Jump frequency 2 0.0 to 400.00 Hz 1256h 0.00
1257h
A066 Jump frequency width 2 0.0 to 10.00 Hz 1258h 0.50
Function code Function name Monitoring and setting items Units Run
mode
edit
Modbus
Register
Default