RX Quick Start Guide 39
PARAMETER LIST
A067 Jump frequency 3 0.0 to 400.00 Hz 1259h 0.00
125Ah
A068 Jump frequency width 3 0.0 to 10.00 Hz 125Bh 0.50
A069 Acceleration stop frequency 0.0 to 400.00 Hz 125Ch 0.00
125Dh
A070 Acceleration stop time 0.0 to 60.0 s 125Eh 0.0
A071 PID selection 00: OFF (Disabled)
01: ON (+) (Enabled)
02: ON (+/-) (Reverse output enabled)
– 125Fh 00
A072 PID P gain 0.2 to 5.0 – 1260h 1.0
A073 PID I gain 0.0 to 3600.0 s 1261h 1.0
A074 PID D gain 0.00 to 100.00 s 1262h 0.00
A075 PID scale 0.01 to 99.99 Time 1263h 1.00
A076 PID feedback selection 00: OI
01: O
02: Modbus (RS485 communication)
03: Pulse (Pulse train frequency)
10: Math (Operation function result)
– 1264h 00
A077 Reverse PID function 00: OFF (Deviation = Target value - Feedback value)
01: ON (Deviation = Feedback value - Target value)
– 1265h 00
A078 PID output limit function 0.0 to 100.0 % 1266h 0.0
A079 PID feed forward selection 00: Disabled
01: O
02: OI
03: O2
– 1267h 00
A081 AVR selection 00: Always ON
01: Always OFF
02: OFF during deceleration
– 1269h 02
A082 AVR voltage selection 200-V class: 200/215/220/230/240
400-V class: 380/400/415/440/460/480
V 126Ah -
A085 RUN mode selection 00: Normal operation
01: Energy-saving operation
02: Automatic operation
– 126Dh 00
A086 Energy-saving response/accuracy adjustment 0.0 to 100.0 – 126Eh 50.0
A092 Acceleration time 2 0.01 to 3600.00 s 1274h 10.00
1275h
A292 2nd acceleration time 2 0.01 to 3600.00 s
226Fh 10.00
2270h
A392 3rd acceleration time 2 0.01 to 3600.00 s
326Dh 10.00
326Eh
A093 Deceleration time 2 0.01 to 3600.00 s 1276h 10.00
1277h
A293 2nd deceleration time 2 0.01 to 3600.00 s
2271h 10.00
2272h
A393 3rd deceleration time 2 0.01 to 3600.00 s
326Fh 10.00
3270h
A094 2-step acceleration/deceleration selection 00: 2CH-terminal (Switched via multi-function input 09)
01: Preset FQ (Switched by setting)
02: FWD-REV (Enabled only when switching forward/
reverse)
– 1278h 00
A294 2nd 2-step acceleration/deceleration selection 00: 2CH-terminal (Switched via multi-function input 09)
01: Preset FQ (Switched by setting)
02: FWD-REV (Enabled only when switching forward/
reverse)
–
2273h 00
A095 2-step acceleration frequency 0.00 to 400.00 Hz 1279h 0.00
127Ah
A295 2nd 2-step acceleration frequency 0.00 to 400.00 Hz
2274h 0.00
2275h
A096 2-step deceleration frequency 0.00 to 400.00 Hz 127Bh 0.00
127Ch
A296 2nd 2-step deceleration frequency 0.00 to 400.00 Hz
2276h 0.00
2277h
A097 Acceleration pattern selection 00: Line
01: S-curve
02: U-curve
03: Inv. U curve
04: EL-S curve
– 127Dh 01
A098 Deceleration pattern setting 00: Line
01: S-curve
02: U-curve
03: Inv. U curve
04: EL-S curve
– 127Eh 01
A101 OI start frequency 0.00 to 400.00 Hz 1281h 0.00
1282h
A102 OI end frequency 0.00 to 400.00 Hz 1283h 0.00
1284h
A103 OI start ratio 0 to OI end ratio % 1285h 20
A104 OI end ratio OI start ratio to 100 % 1286h 100
Function code Function name Monitoring and setting items Units Run
mode
edit
Modbus
Register
Nº
Default