b046 Reverse rotation prevention selection 00: OFF (Disabled)
01: ON (Enabled)
– 1330h 00
b049 Dual rate selection 00: CT (Constant torque)
01: VT (Variable torque)
– 1333h 00
b050 Selection of non-stop function at momentary power
interruption
00: OFF (Disabled)
01: V-Cnst (STOP) (Enabled (deceleration stop))
02: NS1 (Enabled (without recovery))
03: NS2 (Enabled (with recovery))
– 1334h 00
b051 Starting voltage of non-stop function at momentary
power interruption
0.0 to 1000.0 V 1335h 220/400
b052 Stop deceleration level of non-stop function at
momentary power interruption
0.0 to 1000.0 V 1336h 360/720
b053 Deceleration time of non-stop function at momen-
tary power interruption
0.01 to 360.00 s 1337h 1.00
1338h
b054 Deceleration starting width of non-stop function at
momentary power interruption
0.00 to 10.00 Hz 1339h 0.00
b055 Proportional gain setting of non-stop function at
momentary power interruption
0.00 to 2.55 – 133Ah 0.20
b056 Integral time setting of non-stop function at momen-
tary power interruption
0.000 to 65.535 s 133Bh 0.100
b060 Window comparator O upper limit level 0 to 100 % 133Fh 100
b061 Window comparator O lower limit level 0 to 100 % 1340h 0
b062 Window comparator O hysteresis width 0 to 10 % 1341h 0
b063 Window comparator OI upper limit level 0 to 100 % 133Fh 100
b064 Window comparator OI lower limit level 0 to 100 % 1340h 0
b065 Window comparator OI hysteresis width 0 to 10 % 1341h 0
b066 Window comparator O2 upper limit level -100 to 100 % 1345h 100
b067 Window comparator O2 lower limit level -100 to 100 % 1346h -100
b068 Window comparator O2 hysteresis width 0 to 10 % 1347h 0
b070 Analog operation level at O disconnection 0 to 100
no: Ignored
% 1349h no
b071 Analog operation level at OI disconnection 0 to 100
no: Ignored
% 134Ah no
b072 Analog operation level at O2 disconnection 0 to 100
no: Ignored
%
134Bh no
b078 Integrated power clear Cleared with the Enter key after changing to 01 – 1351h 00
b079 Integrated power display gain 1 to 1000 – 1352h 1
b082 Starting frequency 0.10 to 9.99 Hz 1355h 0.50
b083 Carrier frequency 0.5 to 15.0 (0.4 to 55 kW) kHz 1356h 5.0
0.5 to 10.0 (75 to 132 kW) 3.0
b084 Initialization selection 00: no (Clears the trip monitor)
01: Trip data (Initializes data)
02: Parameters (Clears the trip monitor and initializes
data)
03: Trip+Param (Clears the trip monitor and parame-
ters)
04: Trip+Prm+EzSQ (Clears the trip monitor, parame-
ters and Drive Program)
– 1357h 00
b085 Initialization parameter selection 01 (Do not change) – 1358h 01
b086 Frequency conversion coefficient 0.1 to 99.9 – 1359h 1.0
b087 STOP key selection 00: ON (Enabled)
01: OFF (Disabled)
02: Only RESET (Disabled only during stop)
– 135Ah 00
b088 Free-run stop selection 00: 0 Hz start
01: f-match (Frequency matching start)
02: Actv. f-match (Active frequency matching restart)
- 135Bh 00
b089 Automatic carrier reduction 00: OFF (Disabled)
01: ON (Enabled)
– 135Ch 00
b090 Usage of regenerative braking function 0.0 to 100.0 % 135Dh 0.0
b091 Stop selection 00: Decel-Stop
01: Free-RUN
– 135Eh 00
b092 Cooling fan control 00: Alws-ON (Always ON)
01: ON in RUN (ON during RUN)
– 135Fh 01
b095 Regenerative braking function operation selection 00: OFF (Disabled)
01: RUN-ON (Enabled (Disabled during stop))
02: Alws-ON (Enabled (Enabled during stio))
– 1362h 00
b096 Regenerative braking function ON level 330 to 380
660 to 760
V 1363h 360/720
b098 Thermistor selection 00: Disabled
01: PTC enabled
02: NTC enabled
– 1365h 00
b099 Thermistor error level 0 to 9999 1366h 3000
b100 Free V/F frequency 1 0 to free V/F frequency 2 Hz 1367h 0
b101 Free V/F voltage 1 0.0 to 800.0 V 1368h 0.0
b102 Free V/F frequency 2 0 to free V/F frequency 3 Hz 1369h 0
b103 Free V/F voltage 2 0.0 to 800.0 V 136Ah 0.0
b104 Free V/F frequency 3 0 to free V/F frequency 4 Hz 136Bh 0
b105 Free V/F voltage 3 0.0 to 800.0 V 136Ch 0.0
b106 Free V/F frequency 4 0 to free V/F frequency 5 Hz 136Dh 0
b107 Free V/F voltage 4 0.0 to 800.0 V
136Eh 0.0
b108 Free V/F frequency 5 0 to free V/F frequency 6 Hz 136Fh 0
b109 Free V/F voltage 5 0.0 to 800.0 V 1370h 0.0