203
Adjustment Level Section 5-4
This parameter sets the time for the control operation when using the sim-
ple program function.
The set value is saved in the Soak Time parameter for the current bank.
Related Parameters
Program start, Soak time remain (operation level): Page 184
Bank * wait band, Bank * soak time (Bank setting level): Page 215
Program pattern (initial setting level): Page 229
Soak time unit (advanced function setting level): Page 266
This parameter sets the stable band within which the soak time is mea-
sured for the simple program function.
The set value is saved in the Soak Time parameter for the current bank.
Related Parameters
Program start, Soak time remain (operation level): Page 184
Bank * wait band, Bank * soak time (Bank setting level): Page 215
Program pattern (initial setting level): Page 229
Soak time unit (advanced function setting level): Page 266
soak Soak Time
The Program Pattern parameter
must not be set to OFF.
Setting range Unit Default
1 to 9999 min or h 1
Function
Setting
See
See
wt-b Wait Band
The Program Pattern parameter
must not be set to OFF.
Model Setting range Unit Default
Temperature input OFF or 0.1 to
3240.0
°C or °F off
Analog Input OFF or 0.01 to
99.99
%FS
Function
Setting
See
See