Error message Troubleshooting
The communication time-out is oc-
curred.
Switch off controller, verify the following contents and then restart.
Is cable connected correctly?
Does it comply with communication specifications of external devices?
Are external devices functioning normally?
If error is not resolved after confirmation, the controller may be damaged.
Please discuss this with one of our branches or regional offices.
Refer to Non-procedure Communications - Communications
Specifications Settings in the Vision System FH/FHV Series User’s
Manual for Communications Settings (Cat. No. Z342).
Failed to transfer data.
The free capacity of RAMDisk may
insufficient.
Increase the free capacity of RAM-
Disk and then perform this opera-
tion again.
Clean up the content of RAMDisk to increase free space. If this error oc-
curs even though enough free space is available, scene group data may
be too large. Review the inspection flow.
Do you want to scan and fix Re-
movable Disk(*:)?
There might be a problem with
some files on this device or disc.
This can happen if you remove the
device or disc before all files have
been written to it.
The external storage which is inserted to the driver is possible to be ab-
normal.
Select Continue without scanning, confirm the external storage of your
PC.
Error in input range. Please input
using the correct range.
Please verify range for setting and set up again.
File name contains invalid charac-
ter.
Please confirm that characters such as \ / , : ; * ? " < > |& . SPC (space)
are not included in the file name.
Failed to save file. Please check. Check the following points.
Is the memory of the save destination sufficient?
For cases where the save destination is the folder in the USBDisk, is
the USBDisk connected to the controller? Or, the controller may not
have detected the USBDisk.
Fan/voltage error. Switch off controller, and verify if fan is affected. If error message is still
shown after restart, the controller may be damaged. Please contact one
of our branches or regional offices.
The error concerning parallel inter-
face was detected. Turn OFF the
power and check the connection
state of the parallel interface.
Turn off the power, and then confirm the following points of parallel inter-
face communication.
Is the parallel interface output directly connected to the power or GND?
The reason why current load is exceeded because the resistive load
value of the connected parallel interface is low.
ProcItem error
xxxx: xxxxerror
This is displayed when the application software detects an abnormality.
Please contact one of our branches or regional offices as there may be a
software trouble.
11 What to Do!
11 - 5
FH/FHV Series Vision System User’s Manual (Z365-E1)
11-1 Error Messages and Troubleshooting
11

Table of Contents

Other manuals for Omron fh series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh series and is the answer not in the manual?

Omron fh series Specifications

General IconGeneral
TypeMachine Vision System
SeriesFH Series
Power Supply24 VDC
Storage Temperature-20 to 60°C
Humidity35 to 85% RH (non-condensing)
Image SensorCMOS
Processing SpeedHigh-speed processing
ConnectivityEthernet
I/ODigital I/O
Operating SystemEmbedded OS
I/O PortsEthernet, USB