PLC Link Connections
388
FQ2-S4 User’s Manual
Command Tables for PLC Link Communications
This section describes the commands used in PLC Link communications.
Measurement Control Commands
Utility Commands
Scene Control Commands
First word of com-
mand area (hex)
Command name Function Reference
+2 +3
1010 0010 Single Measurement Performs a single measurement. p. 389
1020 0010 Start Continuous Measure-
ments
Executes continuous measurements. p. 390
1030 0010 End Continuous Measure-
ments
Ends continuous measurements. p. 390
First word of com-
mand area (hex)
Command name Function Reference
+2 +3
2010 0010 Clear Measurement Values Clears all measurement result values. p. 391
3010 0010 Save Data in Sensor Saves the current system data and scene
groups in the Sensor.
p. 391
4010 0010 Re-register Model Registers the model again. p. 391
4020 0010 External Teaching Performs reteaching. p. 392
F010 0010 Reset Vision Sensor Resets the Vision Sensor. p. 392
First word of com-
mand area (hex)
Command name Function Reference
+2 +3
1000 0020 Get Scene Number Acquires the current scene number. p. 393
1000 0030 Select Scene Changes to the specified scene number. p. 393