Menu Tables
FQ2-S4 User’s Manual
469
Appendices
12
Setting
(OCR)
Verification
Verif. master data Sets whether to verify the read charac-
ter string against a character string
that is registered in the master data.
Sets the character string to use to ver-
ify the read character string against
the master data.
OFF (default), All master data, or Mas-
ter data 0 to 31
Scene
Master data regist. Registers a character string in the
master data.
Master data 0 to 31 Scene
[MENU]
Auto Reads a character string from an input
image and registers it in the master
data.
--- Scene
Insp.
region
Manual
L.1 to L.4 A character string is entered directly in
the master data.
32 alphanumeric characters Scene
Item ref.
Ref. data Registers the immediately preceding
read results as a verification character
string.
--- Scene
L.1 verif.
range to
L.4 verif.
range
Sets the beginning and end characters
to verify.
1 to 1024 (defaults: beginning: 1, end:
1024)
Scene
Copy Copies or clears registered master
data.
--- Scene
Delete
Auto teach No. Sets the character string in the master
data in which to automatically register
the read result for teaching from an
external device.
OFF or Master data 0 to 31 Scene
(Bar code, 2D-code, 2D-code (DPM))
Verif. master data Sets whether to verify the read charac-
ter string against a character string
that is registered in the master data.
Sets the character string to use to ver-
ify the read character string against
the master data.
OFF, All master data (default), or Master
data 0 to 31
Scene
Master data regist. Registers a character string in the
master data.
Master data 0 to 31 Scene
[MENU]
Auto Reads a character string from an input
image and registers it in the master
data.
--- Scene
Insp.
region
Manual
L.1 to L.4 Registers a character string directly in
the master data.
32 alphanumeric characters Scene
Item ref.
Ref. data Registers the immediately preceding
read results as a verification character
string.
--- Scene
Line 1
verif.
range to
Line 4
verif.
range
Sets the beginning and end characters
to verify for each line.
1 to 1024 (defaults: beginning: 1, end:
1024)
Scene
Copy Copies or clears registered master
data.
--- Scene
Delete
Menu command Description Setting range Data Refer-
ence