Menu Tables
FQ2-S4 User’s Manual
483
Appendices
12
Sensor settings
Information Used to check the Sensor information. --- --- p. 277
Model Used to check the model and software
version of the connected Sensor.
--- System
Version
Name Displays the name of the connected
Sensor.
MAC address Used to check the MAC address of the
connected Sensor.
--- ---
Rename Used to change the name of a con-
nected Sensor.
15 alphanumeric characters max. --- p. 278
Memory
state
Used to check the status of Sensor
memory.
--- --- p. 278
Error history View his-
tory
Displays a history of errors that have
occurred in the Sensor.
--- System p. 452
Delete his-
tory
Deletes the error history. --- p. 453
Startup set-
tings
Startup
mode
Sets whether the startup scene number
is set manually.
ON or OFF (Scene number when set-
tings were saved is startup scene num-
ber.)
System p. 236
Startup
scene
Set the scene number to use at startup. Standard models: 0 to 31, Single-func-
tion models: 0 to 7, Default: 0
Password
settings
Password
ON/OFF
Enables (ON) or disables (OFF) the
password.
OFF (default) or ON System p. 267
Enter
password
Sets a password. 15 characters max.
Retry details
Timeout Sets the timeout time during measure-
ments.
100 to 30000 ms (default:30000 ms) System
Retry mode Sets the type of retry for measurements. Normal retry, Expose retry, Scene retry,
Trigger retry, or None (default)
System
Switch Order (for
Scene retry only)
Sets the method for changing scenes. Auto (default) or Fixed System
Retry scene (for
Scene retry only)
Changes the order in which to change
the scenes.
Scenes are registered in order from the
first scene.
1st to 32nd System
Adjustment mode in
Run
Sets whether to adjust measurement
contents in Run Mode.
OFF (default) or ON --- p. 231
Network settings
Ethernet p. 53
IP address set-
ting
Sets the method to use to set IP
addresses.
Auto (default), Fixed, DHCP System
IP address Enter the IP address of the Sensor.
(Valid only when the [IP address setting]
is set to [Fixed].)
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 2 to 254
(Default: 10.5.5.100)
System p. 53
Subnet mask Inputs the subnet mask.
(Valid only when the [IP address setting]
is set to [Fixed].)
0.0.0.0 to 255.255.255.255
(Default: 255.255.255.0)
System p. 53
Gateway Sets the default gateway address. (When
the [IP address setting] is set to [Fixed].)
1.0.0.1 to 223.255.255.254
(Default: 10.5.5.7)
System
Menu command Description Setting range Data Refer-
ence

Table of Contents