Menu Tables
484
FQ2-S4 User’s Manual
Sensor settings
Data output
No-protocol data
Communication
type
Sets the communications type to use to
output no-protocol data.
Invalid (default), No protocol (TCP), No
protocol (FINS), No protocol (RS-232C)
System p. 402,
p. 448
When the com-
munications type
is TCP no-proto-
col or FINS/TCP
no-protocol
Connec-
tion mode
Sets whether to communicate with the
communications devices as a server
device or a client device.
TCP server (default), TCP client System p. 402
IP address Sets the IP address to which to output
no-protocol data.
* Setting is not possible if the connection
mode is set to a TCP server.
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
(Default:10.5.5.111)
System p. 402
Port No. Sets the output port number.
* Setting is not possible if the connection
mode is set to a TCP server.
0 to 65535 (Default: 9600) System p. 402
Data output
No-protocol data
When the com-
munications type
is RS-232C no-
protocol
Baud rate Set the baud rate to use for RS-232C
communications.
2400, 4800, 9600, 19200, 38400, 57600,
or 115200 (default: 38400)
System p. 448
Data
length
Sets the data length. 7bit or 8bit (default: 8bit) System p. 448
Parity Sets the parity. None, Odd, Even (default: None) System p. 448
Stop bit Sets the number of stop bits. 1bit, 2bit (default: 1bit) System p. 448
Flow con-
trol
Sets the controls for the flow of commu-
nications with the software.
None, Xon/Xoff (default: None) System p. 448
Delimiter Set the delimiter to add to the end of
commands and responses.
CR, LF, or CR+LF (default:CR) System p. 448
Interval
timeout
(text)
Timeout [s] Set the time in seconds to
generate a timeout error.
1 to 120 s, 0: Not monitored.
(default: 0 s)
System p. 448
Interval
time-
out(after
Xoff
reception)
Timeout [s] Set the time in seconds to
generate a timeout error.
1 to 120 s, 0: Not monitored.
(default: 0 s)
System p. 448
Link data output
Communication
type
Sets the communications type to use for
EtherNet/IP or PLC Link outputs.
Invalid (default), PLC link (SYSMAC)
PLC link (MELSEC), EtherNet/IP
System p. 375
Area set-
tings(Only when
communications
type is PLC Link)
p. 376
Command
Area type
Sets the area to write command data to
the Sensor.
Control inputs, command codes, and
command parameters are written to this
area.
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0 to EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
System
Address
Set the first address of the command
area.
0 to 99,999 (default: 0) System
Menu command Description Setting range Data Refer-