Sensor settings
Data output
Link data output
Area settings
Response
Area type
Sets the area to write execution results
from the Sensor.
Control outputs, command codes,
response codes, and response data
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default), Work Area
(WR), Holding Bit Area (HR), Auxiliary
Bit Area (AR), DM Area (DM), EM Area
(EM0 to EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
System p. 376
Address
Set the first address of the response
area.
0 to 99999 (default: 100) System
Output
Area type
Sets the area to write output data from
measurements.
Output data 0 to 31
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0)
EM Area (EM1)
:
EM Area (EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
System p. 376
Address
Set the first address of the output area . 0 to 99999 (default: 200) System
Output hand-
shake
Sets whether to establish an interlock
with the PLC when data is output.
No (default) or Yes System p. 376
Retry details Enables or disables retrying communica-
tions.
This can be set only when the communi-
cations type is set to a PLC Link.
ON or OFF (default) System p. 376
Retry interval Sets the interval for retrying communica-
tions.
This setting is enabled only when [Retry
details] is set to [ON].
This can be set only when the communi-
cations type is set to a PLC Link.
0 to 2,147,483,647 ms (default:10,000
ms)
System p. 376
Max output data Sets the upper limit of the number of out-
put data to use for PLC Link outputs.
Any output data that is beyond this value
is discarded.
This can be set only when the communi-
cations type is set to a PLC Link.
32 to 1024 (default: 256) System p. 376
Output data size Sets the data size to output for EtherNet/
IP output.
If the data size that is set is exceeded,
data will be output in more than one
transfer.
This can be set only when the communi-
cations type is set to EtherNet/IP.
32 bytes (default), 64 bytes, 128 bytes, or
256 bytes
System p. 336
Connection
mode
Sets the TPC connection mode. TCP server (default) or TCP client System
Refreshing task
period
Set the communications cycle for cyclic
tag data link communications for the
Vision Sensor.
This can be set only when the communi-
cations type is set to EtherNet/IP.
1 to 10,000 ms (default:10 ms) System p. 336
Timeout Sets the timeout time when handshaking
is enabled.
This can be set only when the communi-
cations type is set to EtherNet/IP.
0.1 to 120.0 s (default: 10 s) System p. 337
Menu command Description Setting range Data Refer-
ence