External Reference Parameters
FQ2-S4 User’s Manual
517
Appendices
12
120 Mea-
sure-
ment
result
Code type Set/acquired
0: Auto
1: DataMatrix
2: QR Code
0 ---
---
121 Code color Set/acquired 0: Auto
1: Black
2: White
0 ---
---
122 Cell (DataMatrix
Square)
Set/acquired 0: Auto
1: 10 × 10
2: 12 × 12
...
16: 64 × 64
0 ---
---
123 Cell (DataMatrix Rect-
angle)
Set/acquired 0: Auto
1: 8 × 18
2: 8 × 32
...
16: 16 × 64
0 ---
---
124 Cell (QR Code) Set/acquired 0: Auto
1: 21 × 21
2: 25 × 25
...
10: 57 × 57
0 ---
---
127 Size Set/acquired 50 to 480 480 --- ---
128 Reverse Set/acquired 0: Auto
1: Normal
2: Reverse
0 ---
---
129 QR Code Model Set/acquired 0: Auto
1: Model 1
2: Model 2
0 ---
---
130 Error Correction Level Set/acquired 0: Auto
1: M (15%)
2: L (7%)
3: H (30%)
4: Q (25%)
0 ---
---
131 Mea-
sure-
ment
result
Timeout time (ms) Setting/Acqui-
sition
1 to 9999 9999 --- ---
132 Fast mode Set/acquired 0: OFF 1: ON 0 --- ---
133 Output
parame-
ter
String output on/off Set/acquired
0: OFF 1: ON 0 --- ---
134 Partial output on/off Set/acquired 0: OFF 1: ON 0 --- ---
135 Output end digit Set/acquired 1 to 1024 1024 --- ---
136 Output starting digit Set/acquired 1 to 1024 1 --- ---
137 Mea-
sure-
ment
result
Auto length Set/acquired
0: OFF 1:ON 1 --- ---
138 Output
parame-
ter
NG String output on/off Set/acquired
0: OFF 1: ON 0 --- ---
140 Error string Setting/Acqui-
sition
0: OFF 1: ON 0 --- ---
External
refer-
ence
number
Category Data name Set/acquired Data range Default Text string
assigned
to
Ethernet
output
setting
Logged