6
6-17
6-5 Encoder Dividing Function
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Applied Functions
90° Phase Difference Output Type External Encoder
Phase Z is output without dividing the Z signal that is input from the 90° phase difference output
type external encoder.
When 90
° Phase Difference Output External Encoder Pulse Output Method Selection (Pn622) =
1, the phase AB signal can be input into the amplifier and regenerated. Note, in this case, that the
phase-AB regeneration will be delayed compared to when Pn622 is set to 0.
External Encoder Common Items
When detection cannot be made because the phase-Z signal width is narrow due to the external
encoder travel distance, if you set the phase-Z signal output time in the External Encoder-Z
Setting (Pn620), phase Z can be output at least for that period of time.
In addition, take note that the output is made from when the phase-Z signal starts and, therefore,
it will be different from the actual phase-Z signal width. Take note, also, that the direction of the
time extension varies depending on the direction of the operation.
Phase-Z output for pulse regeneration
(before time extension)
Phase-Z output for pulse regeneration
(after time extension)
Pn620 External Encoder Phase-Z Setting
Pn620 External Encoder Phase-Z Setting
Operating direction
Operating direction

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC G5 R88D-KT50F and is the answer not in the manual?

Omron OMNUC G5 R88D-KT50F Specifications

General IconGeneral
BrandOmron
ModelOMNUC G5 R88D-KT50F
CategoryServo Drives
LanguageEnglish

Related product manuals