EasyManua.ls Logo

Omron OMNUC G5 R88D-KT50F

Omron OMNUC G5 R88D-KT50F
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
6-1
6-1 Damping Control
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Applied Functions
6-1 Damping Control
Outline of Operation
If the tip of the mechanical unit vibrates, you can use the damping control function to reduce
vibration.
This is effective on vibration generated by a machine of low rigidity. The applicable frequencies
are from 1 to 200 Hz.
Since damping control is performed using position commands, it cannot be used with speed or
torque control.
Position Controller
Servo Drive
The end vibrates
The damping
frequency changes
based on the position.
Movement

Table of Contents

Related product manuals