3-54
3-7 Parameter List
3
Operation
Options
P001
Operation selection
at option 1 error
00: Trip
01: Continues operation
00 No Yes
4-108
P002
Operation selection
at option 2 error
00: Trip
01: Continues operation
00 No Yes
P011 Encoder pulses
128. to 9999.
1000 to 6553 (10000 to 65535)
1024.
No No Pulse
4-119
4-128
4-129
P012
V2 control mode
selection
00: ASR (speed control mode)
01: APR (pulse train position control mode)
02: APR2 (absolute position control mode)
03: HAPR (High resolution absolute position
control mode)
00 No No
4-119
4-131
P013
Pulse train mode
selection
00: Mode 0
01: Mode 1
02: Mode 2
00 No No 4-122
P014
Orientation stop
position
0. to 4095. 0. No Yes
4-129P015
Orientation speed
setting
Starting frequency to Max. frequency (upper
limit: 120.0)
5.00 No Yes Hz
P016
Orientation direction
setting
00: Forward side
01: Reverse side
00 No No