EasyManua.ls Logo

Omron Sysdrive RX Series - Page 77

Omron Sysdrive RX Series
442 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-28
3-7 Parameter List
3
Operation
RUN mode, Acceleration/Deceleration functions
A085 RUN mode selection
00: Normal operation
01: Energy-saving operation
02: Automatic operation
00 No No
4-36
A086
Energy-saving
response/accuracy
adjustment
0.0 to 100.0 50.0 Yes Yes
A092 Acceleration time 2
0.01 to 99.99
100.0 to 999.9
1000. to 3600.
15.00
Yes Yes s
4-37
A292
* 2nd acceleration
time 2
15.00
A392
* 3rd acceleration
time 2
15.00
A093 Deceleration time 2 15.00
A293
* 2nd deceleration
time 2
15.00
A393
* 3rd deceleration
time 2
15.00
A094
2-step acceleration/
deceleration
selection
00: Switched via multi-function input 09
(2CH)
01: Switched by setting
02: Enabled only when switching forward/
reverse
00
No No
A294
* 2nd 2-step
acceleration/
deceleration
selection
00
A095
2-step acceleration
frequency
0.00 to 99.99
100.0 to 400.0
0.00
No No Hz
A295
* 2nd 2-step
acceleration
frequency
0.00
A096
2-step deceleration
frequency
0.00
No No Hz
A296
* 2nd 2-step
deceleration
frequency
0.00
A097
Acceleration pattern
selection
00: Line
01: S-shape curve
02: U-shape curve
03: Inverted U-shape curve
04: EL-S-shape curve
00 No No
4-38
A098
Deceleration pattern
selection
00 No No
Parameter
No.
Function name Monitor or data range
Default
setting
Changes during
operation
Unit Page
Normal
b031 = 10
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.

Table of Contents

Related product manuals