3-33
3-7 Parameter List
3
Operation
Lock
b031 Soft lock selection
00: Data other than b031 cannot be changed
when terminal SFT is ON.
01: Data other than b031 and the specified
frequency parameter cannot be changed
when terminal SFT is ON.
02: Data other than b031 cannot be
changed.
03: Data other than b031 and the specified
frequency parameter cannot be
changed.
10: Data can be changed during RUN.
01 No Yes 4-51
Others
b034
RUN time/Power ON
time setting
0. to 9999. (0 to 99990)
1000 to 6553 (100000 to 655300)
0. No Yes h 4-52
b035
Rotation direction
limit selection
00: Forward and Reverse are enabled
01: Only Forward is enabled.
02: Only Reverse is enabled.
00 No No 4-52
b036
Reduced voltage
startup selection
0 (Reduced voltage startup time: small) to
255 (Reduced voltage startup time: large)
6NoYes 4-53
b037 Display selection
00: Complete display
01: Individual display of functions
02: User setting
03: Data comparison display
04: Basic display
04 No Yes 4-53
b038
Initial screen
selection
00: Screen when the Enter key was pressed
last
01: d001
02: d002
03: d003
04: d007
05: F001
01 No Yes 4-56
b039
User parameter
automatic setting
function selection
00: Disabled
01: Enabled
00 No Yes 4-57
Parameter
No.
Function name Monitor or data range
Default
setting
Changes during
operation
Unit Page
Normal
b031 = 10
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.