3-46
3-7 Parameter List
3
Operation
Communication function
C071
Communication
speed selection
(Baud rate selection)
02: Loop-back test
03: 2400 bps
04: 4800 bps
05: 9600 bps
06: 19200 bps
04 No Yes
4-141
C072
Communication
station No. selection
1. to 32. 1. No Yes
C073
Communication bit
length selection
7: 7-bit
8: 8-bit
7NoYes
C074
Communication
parity selection
00: No parity
01: Even
02: Odd
00 No Yes
C075
Communication stop
bit selection
1: 1-bit
2: 2-bit
1NoYes
C076
Communication error
selection
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free-run stop
04: Deceleration stop
02 No Yes
C077
Communication error
timeout
0.00 to 99.99 0.00 No Yes s
4-101
4-141
C078
Communication wait
time
0. to 1000. 0. No Yes ms
4-141
C079
Communication
method selection
00: ASCII
01: ModBus-RTU
01 No Yes
Adjustment
C081 FV adjustment
0. to 9999.
1000 to 6553 (10000 to 65530)
Factor
y
defaul
t
Yes Yes 
C082 FI adjustment
0. to 9999.
1000 to 6553 (10000 to 65530)
Factor
y
defaul
t
Yes Yes 
C083 FE adjustment
0. to 9999.
1000 to 6553 (10000 to 65530)
Factor
y
defaul
t
Yes Yes 
C085
Thermistor
adjustment
0.0 to 999.9
1000.
Factor
y
defaul
t
Yes Yes 4-73
C091 Not used
Use "00".
* Do not change.
00 No No 
Parameter
No.
Function name Monitor or data range
Default
setting
Changes during
operation
Unit Page
Normal
b031 = 10
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.