Maintenance
and
troubleshooting
List
of
self-diagnostic
functions
LED
on
CPU
rack
Message
on
POWER|
RUN
programming
console
display
Power
failure
Turn
on
power.
CPU
failure
Set
PROGRAM
mode
and
perform
power
reset.
Program
may
require
correction.
i
Check
RAM/ROM
for
correct
mounting;
debug
program.
After
MEMORY
ERR
Memory
failure
corrective
action,
perform
failure
reset
operation.
END
instruction
No
END
instruction
at
end
of
program.
Write
in
END
instruction
NO
END
INSTR
missing
error
and
then
perform
failure
reset
operation.
check
bus
line
eonnecuing
the
un
W/O
units.
Check
cable
A
P
isconnection
or
breakage.
When
I/O
link
unit
is
used,
chec!
VO
BUS
ERR
VO
bus
failure
channel
setting
and
optical-fiber
cable
for
breakage.
After
corrective
action,
perform
failure
reset
operation.
Check
battery
for
proper
insertion
into
the
socket.
Replace
if
BATT
LOW
Battery
failure
fully
discharged.
After
corrective
action,
perform
failure
reset
operation.
Xx:
denotes
that
the
indicator
illuminates.
:
denotes
that
the
indicator
goes
off.
©:
denotes
that
the
indicator
blinks.
a.
“Fatal
error”
i.e.,
one
that
causes
the
CPU
to
stop
operating
b.
“Nonfatal
error”
one
that
does
not
cause
the
CPU
to
stop
operating
CPU
failure
a
The
“watchdog
timer”
is
a
timer
that
is
reset
each
time
the
CPU
executes
the
END
instruction.
This
timer
is
used
to
check
the
execution
time
of
the
CPU
when
it
operates
in
the
RUN
or
MONITOR
mode.
When
the
set
time
of
the
watchdog
timer
is
up,
this
indicates
a
failure.
Memory
failure
Sum
check
of
the
memory
is
performed
at
fixed
intervals
to
check
the
memory
contents
and
existence
of
any
abnormal
instruction.
END
instruction
missing
error
Checks
whether
the
END
instruction
is
written
at
the
end
of
the
program.
V0
bus
failure
The
1/O
cable
is
checked
for
breakage.
The
hardware
of
the
I/O
control
section
of
the
PC
is
also
checked.
Battery
failure
Checks
the
supply
voltage
of
the
memory
backup
battery.
By
forming
a
program
as
shown
below
using
special
auxiliary
relay
1808,
an
alarm
signal
can
be
output
to
an
external
device
when
there
is
a
drop
in
the
battery
supply
voltage.
ie

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC C Series and is the answer not in the manual?

Omron SYSMAC C Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC C Series
CategoryController
LanguageEnglish