4-4SectionTypes of Commands and Responses
47
4-4-18 Error Response
If an error occurs during the host communication or lower communication, the
error is identified by the end code.
Response Format
XXXX
Header
End code
The header same as that of the transmitted command
4-4-19 End Code List
The end code is expressed as a 2-digit hexadecimal number.
Type End code Name
Normal 00 Normal completion
7B Warning: Data Carrier battery end
74 Polling command reception
Data Carrier not approaching (when polling inquiry command is issued)
75 Termination of command before processing
(Termination before execution of read/write processing of data)
76 Termination of command after processing
(Termination after execution of read/write processing of data)
Host
10 Parity error
communication
11 Framing/overrun error
14 Command input error
18 Frame length MAX error
Lower
70 Data Carrier communication error
communication
71 Unmatching error
72 Data Carrier missing
7A Address over
7C R/W head not connected
7D Write protect error