5-5SectionChecking Function of the Data Carriers Memory
58
1, 2, 3... 1. Execute MDK1001005 (calculation processing) so that the CRC code
(5CD6
H
) of the data 123456 is written to addresses 0013
H
and 0014
H
.
12
H
34
H
56
H
0010
H
0011
H
0012
H
0013
H
0014
H
5C
H
D6
H
2. Execute MDC1001005 (collation processing). If the result coincides with the
data in the check code area, MD75 will be returned as a normal response.
12
H
34
H
56
H
0010
H
0011
H
0012
H
0013
H
0014
H
5C
H
D6
H
3. If the result does not coincide with the data in the check code area, MD76 will
be returned as a warning.