1-1SectionFeatures
3
DIP Switch 1
Note The V600-CD1D-V2 is set to local communications mode when SW7 is ON.
New Commands The V600-CD1D-V2 incorporates the following new data management com-
mands in order to confirm the reliability of the internal data of the Data Carrier
(DC).
Function Command Processing contents
Checking data MDK By adding a check code to the internal data of the DC, any data errors due to the
SRAM-type DC battery or the number of overwriting operations of the
EEPROM-type DC will be detected.
MDC The MDK command is used to read the check code and the MDC command is
used to check the check code. The MDK command is always used in
combination with the MDC command.
Checking the number
of overwriting
operations
MDL By counting the number of overwriting operations, the life of the EEPROM-type
DC will be detected. The EEPROM-type DC can be overwritten 100,000 times.
Flashing Monitor Function If an error occurs, the display for the code monitor flashes. The display does not
flash if the normal end code or warning code is returned.
Comparing the V600-CD1D-V2 and V600-CD1D-V3
The V600-CD1D-V3 conforms to EC Directives while the V600-CD1D-V2 only
conforms to UL and CSA standards.