EasyManuals Logo

Omron V600 Series User Manual

Omron V600 Series
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
101
RFID System
Operation Manual
Section 5 Communications Commands
Section 5
Communications
1:N Communications
Data code specification Specifies the type of code in which to send the read data in the response.
A: ASCII
H: Hexadecimal
R/W Head No. Specifies the Read/Write Head with which to communicate.
1: Read/Write Head 1
2: Read/Write Head 2
Write area start address Specifies the first address to which to write data to the Data Carrier as a four-digit hexadecimal
number.
Specifiable range: 0000H to FFFFH
No. of write bytes When specifying in odd bytes, this writes the 1 digit prior to the designated data for ASCII code
specification, or the 2 digits of the designated data for hexadecimal specification, to the last 1 byte
of data in the Data Carrier.
Specifiable range: 01H to FFH, 00H (The maximum of 256 bytes will be written if 00H is specified.)
Specified data The data to write to Data Carrier memory.
• ASCII specification: Specify 2 bytes.
• Hexadecimal code specification: Specify 4 bytes.
End code Indicates the results of command execution. An end code of 00 is returned for a normal end.
Refer to End Codes for more information.
p.135
xx
DF
xx
A/H
xx
211 4
2
1/2
xx
xx
2 or 4
3
2
*CR
2
xx
FCS
Controller No.
x
@
x
No. of write
bytes
Specified data
Terminator
Command code
Write area start address
Data code
specifica-
tion
R/W Head No.
Command
Response
Command code
DF
00
22
2
*CR
Terminator
End code
2
xx
FCS
3
Controller No.
x
@
x

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals