129
RFID System
Operation Manual
Section 5 Host Device Commands
Section 5
Communications
1:N Communications
Process code Specifies the Read/Write Head with which to communicate.
00: Read error information
01: Clear error information
End code Indicates the results of command execution.
00: Normal end
Refer to End Codes for more information.
p.135
Most recent error log infor-
mation
The most recent 30 error records from the error log. The most recent error log information is
arranged in the order of occurrence. Five characters are used for each error.
Command
CF
xx
22
2
*CR
2
xx
FC S
3
x
@
x
Controller No.
Command code Process code Terminator
Response
R
Command code
CF
17
00
RD
22 n
2
*CR
Terminator
Most recent error log informationEnd code
xx
2
FCS
3
Controller No.
x
@
x
4
D10
RD 1 70
Error code
Error command
Error head number (for communications errors with Data Carriers only)
A space will be returned for errors other than communications errors with
Data Carriers.

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals