SECTION 3
Set the Communications Conditions for Amplifier Units
CIDRW System
User’s Manual
SECTION 3
Preparing for Communications
Communications conditions
Item Specifications
Standard conformed to RS-232C
Communications control protocol OMRON’s exclusive 1:N or 1:1 protocol
Synchronization method Start-stop synchronization
Baud rate Set using a DIP switch
Frame composition Start bit Data bits Parity bit Stop bit Total
1:N protocol 1 8 None 1 10
1:1 protocol 18Even111
Error detection
1:N protocol FCS (frame check sequence)
1:1 protocol Vertical parity