85
CIDRW System
User’s Manual
SECTION 4
When SECS is Not Used
SECTION 4
Reading from/Writing to ID Tags
■ TEST
Performs a communication test on communications between the host device and Amplifier Unit.
When an Amplifier Unit receives a test command, it sends the response code and command test data
to the host device as the response.
* Number of data n < 136 (2-character units)
The response code (when normal: 00) and the received test data are returned.
Example: Testing by sending the data 12345678 to node No.1
SOH Node No. Command code
Test data
FCS CR
Data 1 ••• Data n
01h 1 0 0Dh
Parameter description
Parameter Description
Test data The data to be sent in the test is specified with a hexadecimal value. (Max. 270 characters)
However, note that odd numbers of characters cannot be used.
SOH Node No.
Response
code
Test data
FCS CR
Data 1 ••• Data n
01h 0 0 0Dh
SOH Node No. Command code
Test data
FCS CR
Data 1 Data 2 Data 3 Data 4
01h01 1 0 12345678080Dh
SOH Node No.
Response
code
Test data
FCS CR
Data 1 Data 2 Data 3 Data 4
01h010012345678090Dh
Command
Response
Command
Response