6.
If
the brushesareat least
0.430
inch
(10.9
mm) long,
rest the brush springs against the sides of brushes
to keep them clear during armature installation. See
Figure
7.
7.
Place washer on commutator end
of
shaft and put
armature into brush endcap. Push the four brushes
toward commutator, making sure springs are prop-
erly positioned on brushes. Recheck to be sure
spring is pushed all the way down on mounting tab.
8.
Make sure all brush wires are clear of commutator
and that uninsulated portions
of
insulated wires do
not touch inside diameter of housing. Uninsulated
portions of wires must also not touch adjacent
brush boxes.
9.
Place magnetic housing over armature. Use a nut
driver over the end
of
shaft to hold down armature
and endcap.
10.
Place spring washer and flat washer on shaft as
shown in Figure
8.
11.
Place mounting bracket on motor with exposed end
of
sleeve bearing and through-bolt"lead-ins"
to
the
inside of motor. The "flat" near one mounting hole
should line up with the positive stud on end cap
so
through-bolts will line up.
,
12.
Insert the through-bolts and torque to
35-45
Ib. in.
(3.96-5.09
Nam).
13.
Wipedustfrom helix and gearand applya light coat
of
GE
Versilube
322-L
on outside diameter
of
helix,
inside diameter
of
gear and unchamfered end
of
gear. Place clutch and helix assembly on motor
shaft with flats engaged in clutch hole.
ES1611
FIGURE
7.
RESTING BRUSH SPRING
ON
BRUSH SIDE
4
Redistribution or publication of this document
by any means, is strictly prohibited.
Redistribution or publication of this document
by any means, is strictly prohibited.