sectors starting at sector offset 234,567: Error # 1: Read error (source),
address=234567, length=64
Note: The default error granularity setting is Standard, which will result in a
minimum chunk of 32KB of source data (64 sectors for a 512B sector drive) that
will get skipped and filled with zeros upon completion of the attempted reads
(assuming no reads were successful). If this condition is encountered, consider
changing the error granularity setting to be Exhaustive, which will result in
repeated read attempts of the error region with decreasing sector sizes. This
will maximize the amount of recoverable data and minimize the sectors that
get skipped and filled with zeros.
If error retries are enabled and TD4 is able to successfully read sector data after an
initial read error is encountered, the Recoverable Errors count shown in the
Acquisition Results section (as shown in the sample log 1, above) will reflect the
number of original read errors encountered. The Unrecoverable Errors count will
reflect read errors for which no retry attempts were successful.