Q9 DUCTED TECHNICAL DATA
Thermal output
Thermal output
Nominal
9.0
kW
Thermal output
Reduced
3.50
Yield
Thermal output
Nominal
87.5
%
Thermal output
Reduced
89.0
Exhaust gas temperature
Thermal output
Nominal
178
°C
Thermal output
Reduced
121
Mass ow of fumes
Thermal output
Nominal
8.18
g/s
Thermal output
Reduced
4.71
Hourly fuel consumption
Thermal output
Nominal
2.15
kg/h
Thermal output
Reduced
0.80
CO emission at 13% oxygen
Thermal output
Nominal
0.025
%
Thermal output
Reduced
0.024
CO emission at 13% oxygen
Thermal output
Nominal
314
mg/Nm³
Thermal output
Reduced
301
Dust at 13% oxygen
20
Minimum ue draught
11
Pa
Maximum allowable working water pressure
--- ---
Hopper capacity
12.5
kg
Mass
120
kg
Dimensions (LxDxH)
700x525x520
mm
Flue gas manifold
80
mm
Minimum safe distance from ammable materials
200
mm
Fuel type
Wood pellets
Can this unit be used with a shared ue
No
Nominal electrical power
315
W
Electrical power during use 110 W
The table below gives the appliance technical data.