APPENDIX "A" AUTOMATIC MODE
The automatic power management systems have the following peculiarities:
no power SETTING menu (also in chrono settings)
20 power levels automatically determined depending on the dierence between the room temperature and the user
temperature SETTING.
the "ECO" operating mode does not exist in which in the other systems the power is reduced to value 1. The "eco" message
indicates that the temperature SETTING has been reached.
the system goes gradually to the working power necessary to maintain the set room temperature.
time
power
Temperature set
temperature level
temperature
power level
In the example, the system goes to balanced conditions maintaining the temperature set at 22.5°C at power level 3.
The evident benets are represented by the following two factors:
1. The constant work power minimises the emissions into the room
2. The lack of oscillations of the power level between minimum (eco) and that set does not generate the consequent
oscillations of the room temperature value.