32
ENGLISH
LIST OF QUICK COMMANDS
Display contrast control
From the main screen, operate on keys P5 and P6 to increase and decrease respectively.
Back-lighting level control
While holding key P3 down, simultaneously operate on keys P5 and P6 to increase and decrease respectively.
Keyboard lock (children's safety)
Activation and deactivation: Press keys P5 and P6 simultaneously and then key P1.
Perform a cleaning cycle (if working)
While holding key P3 down, press key P1 (CHRONO) briey.
PRELIMINARY OPERATIONS
Before commissioning it is necessary to:
Check that all safety conditions envisioned are veried.
Make the electric connection after having checked that the power supply voltage is that prescribed of 230V~ 50Hz.
Remove the bag containing the instructions, radio control and rod for opening the door from the tank.
Check that there is sucient fuel in the tank for the envisioned operating period.
Open the door and check that the re pot is positioned correctly and rests well on the base and that the door of the
combustion chamber closes correctly.
Check that the hand-held radio control is congured with the appliance (see "Conguration with the appliance" chapter).
Check that the hand-held radio control has a sucient battery level.
Before successive rings, proceed as follows when necessary:
Clean the ceramic glass in the door.
Remove any residues from the re pot.
Clean the combustion chamber.
Empty the ash drawer
Eliminate any residual pellets from the tank that were not used for a long time or accumulations of pellet dust as they may
have lost their initial characteristics for good combustion. This operation must be carried out using a suitable suction device.
SWITCHING THE APPLIANCE ON
NOTE
In the case of commissioning, the auger for feeding the fuel is empty, therefore a suitable amount of time is necessary for it
to ll and to feed the re pot; to do this, use the [PRELOADING] function on the user menu.
To switch the appliance on in [MANUAL] mode, press the
button for three seconds. In [MANUAL] mode, with the
appliance on, the green LED positioned at the side of the
button on the appliance command panel also switches on.

Once red, there are 6 operating status present:
[CLEAN]: the smoke extractor goes to maximum speed to clean the re pot from any residues of the previous combustion
[WARM]: the ring heater begins to heat up. The extractor is active.
[LOAD]: the auger feeds the burner with a sucient amount of fuel for the start of combustion. The smoke extractor is
active.
[WAIT]: combustion is triggered in the re pot.
[IGNITION]: the auger feeds the re pot again with a sucient amount of pellets for appliance heating.
[FIRE ON]: the appliance checks the eective and correct start of combustion, controlling ame regularity.
On conclusion of the ring phase, instead of the operating status, the display shows a rectangular bar representing the power
level of current operation. The air fan activates when the smoke temperature has reached the minimum threshold set in the
relative parameter.