33
ENGLISH
There are 20 appliance operating powers managed automatically by the appliance on the basis of room temperature and the
temperature set, in [MANUAL] mode and in [CHRONO] mode.
ATTENTION
If the dierence between the current room temperature and the desired temperature is below 5°C, the appliance will not go
to maximum power (20) but will use the 11th power level as the upper limit.
If ring does not occur, the display signals the alarm [No start].
Before performing a second ring, empty the re pot completely of fuel accumulated in the rst attempt.
Any fuel in the burner must be removed before setting a new lighting operation in all of the following cases:
- after every failed ring,
- whenever the shut-down phase is set, interrupting the lighting phase,
- when relighting following a shutdown due to no pellets.
- for safety reasons, never pour pellets in the hopper.
The operating power is automatically decreased by the appliance as the room temperature approaches the temperature set; on
reaching the temperature set, the appliance positions itself in the ECO status.
If, after the room temperature has reached and exceeded the SETTING set, for particular reasons, e.g. the installation room is
small, the room temperature continues to increase even if the stove/insert is operating at power 1, if the STAND-BY option
has been activated from the user menu, the stove/insert behaves as follows: after 5 minutes that the room temperature has
exceeded the SETTING by 2°C, the stove/insert passes to the switch-o status by passing through the envisioned status.
The STAND-BY status is characterised by the message on the display like in the following image and the LED L2 stove/insert on,
remains active as the stove/insert must be deemed "on".
There is a "lled-in" dot on the display of the hand-held command (in the bottom left) that indicates activation.
The condition for the re-start is that the room temperature goes to a value lower by 2°C with respect to the SETTING and remains
in this condition for at least 10 minutes.