Oracle Database Appliance Specifications
52 Oracle Database Appliance Owner's Guide • March 2017
Item Oracle Database
Appliance X6-2S
Oracle Database
Appliance X6-2M
Oracle Database
Appliance X6-2L
Oracle Database
Appliance X6-2-HA
Nonoperating
temperature
-40
°
C to 70
°
C (-40
°
F
to 158
°
F).
-40
°
C to 70
°
C (-40
°
F
to 158
°
F)
-40
°
C to 70
°
C (-40
°
F
to 158
°
F)
-40
°
C to 70
°
C (-40
°
F
to 158
°
F)
Operating
humidity
10% to 90%
relative humidity,
noncondensing
10% to 90%
relative humidity,
noncondensing
10% to 90%
relative humidity,
noncondensing
10% to 90%
relative humidity,
noncondensing
Nonoperating
humidity
Up to 93%
relative humidity,
noncondensing.
Up to 93% relative
humidity, non-
condensing
Up to 93% relative
humidity, non-
condensing
Up to 93% relative
humidity, non-
condensing
Operating
altitude
Up to 3,000 m* (9,840
ft); maximum ambient
temperature is derated
by 1° C per 300 m
above 900 m
* Except in China
markets where
regulations might
limit installations to a
maximum altitude of
2,000 m (6,560 ft).
Up to 3,000 m* (9,840
ft); maximum ambient
temperature is derated
by 1° C per 300 m
above 900 m
* Except in China
where regulations
might limit installations
to a maximum altitude
of 2,000 m (6,560 ft).
Up to 3,000 m* (9,840
ft); maximum ambient
temperature is derated
by 1° C per 300 m
above 900 m
* Except in China
where regulations
might limit installations
to a maximum altitude
of 2,000 m (6,560 ft).
Up to 3,000 m* (9,840
ft); maximum ambient
temperature is derated
by 1° C per 300 m
above 900 m
* Except in China
where regulations
might limit installations
to a maximum altitude
of 2,000 m (6,560 ft).
Nonoperating
altitude
Up to 12,000 m (39,370
ft)
Up to 12,000 m (39,370
ft)
Up to 12,000 m (39,370
ft)
Up to 12,000 m (39,370
ft)
Cooling For more information
on power consumption,
see Oracle Server X6-2
Power Calculator.
For more information
on power consumption,
see Oracle Server X6-2
Power Calculator.
For more information
on power consumption,
see Oracle Server X6-
2L Power Calculator.
Server node
■ At maximum usage:
1146 BTU/h
■ At typical usage:
485 BTU/h
Storage shelf
■ At maximum usage:
1553 BTU/h
■ At typical usage:
874 BTU/h
Acoustic
noise
7.0 Bels A-weighted
operating, 7.0 Bels A-
weighted idling
7.0 Bels A-weighted
operating, 7.0 Bels A-
weighted idling
8.1 Bels A-weighted
operating, 5.8 Bels A-
weighted idling
7.0 Bels A-weighted
operating, 7.0 Bels A-
weighted idling
Environmental Specifications for Oracle Database Appliance
Version 1 and Models X3-2, X4-2 and X5-2
Item Oracle Database Appliance
Version 1
Oracle Database Appliance
X3-2/X4-2
Oracle Database Appliance
X5-2
Operating
temperature
5
°
C to 35
°
C (41
°
F to 95
°
F). 5
°
C to 35
°
C (41
°
F to 95
°
F) 5
°
C to 35
°
C (41
°
F to 95
°
F)
Nonoperating
temperature
-40
°
C to 70
°
C (-40
°
F to 158
°
F).
-40
°
C to 70
°
C (-40
°
F to 158
°
F)
-40
°
C to 70
°
C (-40
°
F to 158
°
F)