ix Sun SPARC Enterprise T5140 and T5240 Servers Installation Guide December 2010
DC Supply and Ground Conductor Requirements 94
Overcurrent Protection Requirements 95
Assembling and Installing the DC Input Power Cables 95
Assemble the DC Input Power Cables 95
Connect the DC Input Power Cords to the Server 99
Index 101

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Oracle Sun SPARC Enterprise T5140 and is the answer not in the manual?

Oracle Sun SPARC Enterprise T5140 Specifications

General IconGeneral
MemoryUp to 128 GB
Memory Slots16 DIMM slots
Number of Cores8
CPU Clock Speed1.2 GHz
StorageUp to 4 hot-swappable SAS or SATA drives
Network4 integrated Gigabit Ethernet ports
Power SupplyRedundant, hot-swappable power supplies
Form FactorRack-mounted

Summary

Preface

UNIX Commands

Provides references to UNIX commands documentation.

Shell Prompts

Lists shell prompts for different user types.

Related Documentation

Lists related documents available online.

Documentation, Support, and Training

Provides resources for documentation, support, and training.

Documentation Feedback

Instructs users on how to submit feedback for the document.

Preparing for Installation

Server Overview

Describes the T5140 (1U) and T5240 (2U) server form factors.

Server Handling Precautions

Details safety measures for handling servers, including lifting and communication.

Input Power Information and Precautions

Covers AC/DC power supply configurations and safety notes for input power.

Tools and Equipment Needed

Lists essential tools and console devices required for system installation.

Optional Component Installation

Advises on installing factory-optional components before server rack installation.

ESD Precautions

Explains electrostatic discharge prevention measures to protect electronic components.

Installation Overview

Provides a high-level overview of the installation procedures and their order.

Prepare for Installation

Guides on verifying components, gathering configuration info, and installing optional components.

Install the Hardware

Details mounting the server into a rack and connecting to a serial terminal.

Configure the Service Processor

Outlines steps to access and configure the ILOM service processor via serial port.

Configure the Host Software

Covers configuring the Solaris OS, installing patches, and loading optional software.

Cabling Notes for Both Servers

Lists minimum cable connections and details about management ports and Ethernet.

Port, Connector, and LED Locations for Both Servers

Illustrates and identifies rear and front panel ports and LEDs on the servers.

Slide Rail Assembly Notes for Both Servers

Explains the components and differences of slide rail assemblies for the servers.

Cable Management Notes for Both Servers

Describes the use of the cable management arm (CMA) and velcro straps for organizing cables.

Installing the Sun SPARC Enterprise T5140 and T5240 Servers

Installing the Servers in a Rack

Provides instructions for mounting servers into an equipment rack using slide rails.

Install the Slide Rail Assemblies

Details the process of unlocking and attaching slide rail mounting brackets to the server chassis.

Insert and Lock the Server in the Rack

Guides on sliding the server chassis onto the installed slide rails and securing it.

Installing the Cable Management Arm for Both Servers

Explains how to install the Cable Management Arm (CMA) onto the slide rails.

Install the Cable Management Arm

Step-by-step instructions for attaching the CMA rail extension to the slide rails.

Verify the Operation of the Slide Rails and the CMA

Outlines procedures to check the functionality of slide rails and the CMA.

Connecting the Server Cables for Both Servers

Details connecting serial management, network management, and Ethernet cables.

Connect the Service Processor Serial Management Port

Describes connecting a Category 5 cable to the SER MGT port for server management.

Connect the Service Processor Network Management Port

Explains connecting the NET MGT port to the network for remote management.

Connect the Ethernet Network Cables

Guides on connecting network switch or hub to the server's Ethernet ports.

AC Power Cable Notes

Provides notes and cautions regarding AC power cable connections for initial power-on.

Managing Cables With the CMA

Instructions on securing server cables within the Cable Management Arm (CMA).

Secure the Server Cables in the CMA

Details wrapping velcro straps around cables to secure them inside the CMA.

Dismounting the Servers

Explains how to remove a server from the rack for internal part access.

Powering On the System

Powering On the System for the First Time

Provides an overview and instructions for the initial system power-on sequence.

ILOM System Console

Explains the role of the ILOM system console during system boot.

ILOM Service Processor

Describes the ILOM service processor's diagnostics and default network configuration.

Power On the System for the First Time

Step-by-step guide to connecting terminals and powering on the system for the first time.

Enable the Service Processor Network Management Port

Details how to view network configuration, especially if using DHCP.

Logging Into the Service Processor

Guides on accessing the ILOM CLI via serial or network management ports.

Log Into the Service Processor Using the Serial Management Port

Instructions for logging into the ILOM CLI using the serial management port.

Configure the Service Processor Network Management Port

Provides steps to manually reconfigure the network management port settings.

Log Into the Service Processor Using the Network Management Port

Explains how to connect to the service processor using SSH via the network management port.

Using the Service Processor for Common Operations

Covers common operations like system initialization and fault examination using the service processor.

Perform a Normal System Initialization

Details the procedure for performing a normal system initialization via the start /SYS command.

Examine the System for Faults

Guides on checking POST output and using commands to verify system health.

Devices in the OpenBoot Device Tree

Refers to tables for understanding device path names in the OpenBoot device tree.

Booting the Solaris Operating System

Explains how to boot the preinstalled Solaris OS and its initial configuration.

Boot the Solaris Operating System

Provides instructions on booting from disk at the OpenBoot ok prompt.

Avoid Booting the Solaris Operating System at Startup

Mentions setting the auto-boot PROM parameter to false to prevent OS startup.

Reset the System

Details how to reset the system using the shutdown -g0 -i6 -y command.

Power Cycle the System

Outlines the procedure to power cycle the system by shutting down and restarting Solaris OS.

Verifying System Functionality

Suggests using SunVTS software to verify installed components and network connections.

Updating the Firmware

flashupdate command

Explains the flashupdate command for updating SP and server firmware.

Update the Firmware

Guides on updating firmware using SSH, the load command, and a TFTP server.

Installing the Servers With the Express Rail Rackmounting Kit

Slide Rail Assembly Notes for the Express Rail Rackmounting Kit

Provides notes on the express rail kit, its components, and installation differences.

Install the Slide Rail Assemblies

Details unlocking and attaching the express rail mounting brackets and slide rails.

Insert and Lock the Server in the Rack

Guides on sliding the server onto the rack rails and securing it.

Dismounting the Server

Explains how to remove a server from the rack to access internal parts.

Assembling and Installing DC Power Cables for the Sun SPARC Enterprise T5140 Server

Requirements for Servers With DC Input Power

Lists restrictions for T5140 servers using DC input power, like restricted location.

DC Supply and Ground Conductor Requirements

Specifies conductor material, gauge, insulation, and connector requirements for DC power.

Overcurrent Protection Requirements

Details necessary overcurrent protection devices and circuit breaker specifications.

Assembling and Installing the DC Input Power Cables

Explains how to assemble DC input power cables, including strain relief and connectors.

Assembling and Installing DC Power Cables for the Sun SPARC Enterprise T5240 Server

Requirements for Servers With DC Input Power

Lists restrictions for T5240 servers using DC input power, like restricted location.

DC Supply and Ground Conductor Requirements

Specifies conductor material, gauge, insulation, and connector requirements for DC power.

Overcurrent Protection Requirements

Details necessary overcurrent protection devices and circuit breaker specifications.

Assembling and Installing the DC Input Power Cables

Explains how to assemble DC input power cables for the T5240 server.