ZS3-2 Electrical Specifications
The ZS3-2 controller electrical specifications are listed below. The power dissipation numbers
listed are the maximum rated power numbers for the power supply. The numbers are not a
rating of the actual power consumption of the appliance.
Connectors
Two C13 connectors, which work on 110-220v outlets
Input
Nominal frequencies: 50/60Hz (47 to 63 Hz range)
Nominal voltage range: 100 to 120/200 to 240 VAC
Maximum current AC RMS: 6.8 A @ 100-120 V / 3.4 A @ 200-240 V
AC operating range: 90-264 VAC
Output
3.3 VDC STBY: 3.0A
+12 VDC: 86.7A
Power Dissipation
Max power consumption: 890 W max
Max heat output: 3026 BTU/hr
Volt-Ampere rating: 908 VA @ 240 VAC, 0.98P.F.
ZS3-2 Acoustic Noise Emissions
In compliance with the requirements defined in ISO 7779, the workplace-dependent noise level
of this product is less than 70 db (A).
ZS3-2 Configuration Options
The ZS3-2 controller is an enterprise-class, rackmount x86 system powered by the Intel Xeon
processor. It provides high performance and room for growth with expandable PCIe slots and
16 DIMM slots in a compact 2U footprint. The following table describes the configuration
options.
Installation Prerequisites and Hardware Overviews 39