76 Symbion™ Programmer Guide © Orbotech 2005
Draft - Confidential
• M
ax Unrecognized Chars defines the number of characters that may not
be read in any given Expected Text.
Setting 0 the system attempts to read all objects.
Max Unrecognized Chars is not compatible with the use of
wildcards (* or ?) in Expected Text
• Case Sensitive when on (with check box) the Expected Text is case
sensitive.
• Use Plausible Pairs when on (with check box) the read text is compared to
the Expected Text and allowance is made for defined pairs of characters.
Plausible Pairs may be reviewed and defined in the
OCR Training Manager
• Minimum Length defines the minimum expected length of the read text, if
fewer characters are found the inspection will fail.
Setting 0 no Minimum Length is required.
• Maximum Length defines the maximum expected length of the read text,
if more characters are found the inspection will fail.
Setting 0 no Maximum Length is required.
The value of both Minimum and Maximum Length includes
unrecognized characters (which are shown in the result as ~)
• FontId defines the font to be used for trained recognition.
When no FontId is set, no trained recognition will be carried out (see
Training Characters).