110
Indicator Lamp
Recorder Status
REC
(Red)
READY
(Green)
BUSY
(Red)
Status immediately after power-on
Recorder booting
Live video display
∗
1
Normal recording
∗
1,
∗
2
Intermittent recording
∗
1,
∗
2
• Postrecording
∗
1
• Including PC application operation
∗
3
Administrator setting screen display with
recording stopped
(not accessing P2 card)
Administrator setting screen display with
recording stopped
(accessing P2 card)
Playing
• Terminating operation
• P2 card start processing (recognition when
inserted)
• P2 card shutdown processing (when a P2
card slot cover is opened)
Updating recorder firmware
• Updating microprocessors on the recorder
and Remote Control Panel
• Copying menu settings
Successfully copied the menu settings
Failed to copy menu settings
, or
An error involving recording operations occurred
during live screen display
∗
4
• The recorder's P2 card slot cover is open
• No P2 card is inserted, or it is not recognized
• No more P2 card space available
• The write-protect switch of the P2 card is set
to “PROTECT”
<When using 16 GB or higher capacity P2 cards>
• A new unformatted card
• When the maximum number of recording
days or files has been exceeded
•
When P2 card folders have been manipulated
on a PC
Indicator Lamps and Recorder Status
This table shows the relationship between lamp Lit/Unlit/blinking states and the
recorder’s operating status.
: Lit : Normal blinking : Unlit : Fast blinking (about three times/sec)
: Blinking consisting of short off intervals combined with long on intervals