EasyManua.ls Logo

Panasonic AJ-D230H - Set-up Menu: BASIC Options; Display Selection (DISPLAY SEL); Character Position and Type; Menu Inhibit Function

Panasonic AJ-D230H
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-8
2-6. AJ-D950, AJ-D950A
<Table of Test Point>
Name AJ-D950, AJ-D950A
[ Tension Arm Adjustment ]
TENSION SERVO (F1) : TP201
TENSION OFFSET MECHA I/F : VR1
TENSION GAIN MECHA I/F : VR2
[ Photo Sensor Voltage Adjustment ]
S-side Output SYSCON (F2) : P2 25PIN
T-side Output SYSCON (F2) : P2 26PIN
Adjustment Point MECHA I/F : SW200
[ Tape Pass, A/C Head Adjustment ]
R/P-ENV L RF (H3) : TP201
R/P-ENV R RF (H4) : TP201
PB-ENV L RF (H3) : TP101
PB-ENV R RF (H4) : TP101
FP-S0 (FRAME PULSE) SERVO (F1) : TP301
R/P-HSW L SERVO (F1) : TP722
PB-HSW L SERVO (F1) : TP723
LIVE-CTL SERVO (F1) : TP30
CUE CUE (H1) : TP101
[ LISTA Adjustment ]
ATF ERR SERVO (F1) : TP732
TRG R/P-HSW L SERVO (F1) : TP722
PB-HSW L SERVO (F1) : TP723
GND SERVO (F1) : TG510
ATF GAIN Select the EVR on the Service Menu.
(Refer to below table <LISTA Adjustment Mode)
<A/C Head Adjustment Mode>
Adjustment Name Format Select Adjustment Mode (Select on the Service Menu)
Azimuth, X Value Adj. 25M Select the item A10 : RP LINEAR DP.
50M Select the item A06 : RP LINEAR ED.
<LISTA Adjustment Mode>
Adjustment Mode
Adjustment Name Format Select
(LISTA Software) Service Menu Item TRG Connection
Sens. Adjustment (R/P Head) A05 : RP GAIN ED R/P-HSW L
Linearity Adjustment 50M mode A06 : RP LINEAR ED R/P-HSW L
Sens. Adjustment (PB Head) A07 : PB GAIN ED PB-HSW L
Sens. Adj. (R/P Head) 25M compatible A09 : RP GAIN DP R/P-HSW L
Linearity Adjustment 25M compatible 25M mode A10 : RP LINEAR DP R/P-HSW L
Sens. Adj. (PB Head) 25M compatible A11 : PB GAIN DP PB-HSW L