2-8
2-6. AJ-D950, AJ-D950A
<Table of Test Point>
Name AJ-D950, AJ-D950A
[ Tension Arm Adjustment ]
TENSION SERVO (F1) : TP201
TENSION OFFSET MECHA I/F : VR1
TENSION GAIN MECHA I/F : VR2
[ Photo Sensor Voltage Adjustment ]
S-side Output SYSCON (F2) : P2 – 25PIN
T-side Output SYSCON (F2) : P2 – 26PIN
Adjustment Point MECHA I/F : SW200
[ Tape Pass, A/C Head Adjustment ]
R/P-ENV L RF (H3) : TP201
R/P-ENV R RF (H4) : TP201
PB-ENV L RF (H3) : TP101
PB-ENV R RF (H4) : TP101
FP-S0 (FRAME PULSE) SERVO (F1) : TP301
R/P-HSW L SERVO (F1) : TP722
PB-HSW L SERVO (F1) : TP723
LIVE-CTL SERVO (F1) : TP30
CUE CUE (H1) : TP101
[ LISTA Adjustment ]
ATF ERR SERVO (F1) : TP732
TRG R/P-HSW L SERVO (F1) : TP722
PB-HSW L SERVO (F1) : TP723
GND SERVO (F1) : TG510
ATF GAIN Select the EVR on the Service Menu.
(Refer to below table <LISTA Adjustment Mode)
<A/C Head Adjustment Mode>
Adjustment Name Format Select Adjustment Mode (Select on the Service Menu)
Azimuth, X Value Adj. 25M Select the item “A10 : RP LINEAR DP”.
50M Select the item “A06 : RP LINEAR ED”.
<LISTA Adjustment Mode>
Adjustment Mode
Adjustment Name Format Select
(LISTA Software) Service Menu Item TRG Connection
Sens. Adjustment (R/P Head) “A05 : RP GAIN ED” R/P-HSW L
Linearity Adjustment 50M mode “A06 : RP LINEAR ED” R/P-HSW L
Sens. Adjustment (PB Head) “A07 : PB GAIN ED” PB-HSW L
Sens. Adj. (R/P Head) 25M compatible “A09 : RP GAIN DP” R/P-HSW L
Linearity Adjustment 25M compatible 25M mode “A10 : RP LINEAR DP” R/P-HSW L
Sens. Adj. (PB Head) 25M compatible “A11 : PB GAIN DP” PB-HSW L