2-51
3-33. LISTA Linearity Adjustment and Waving Measurement
SPEC. Linearity : less than 3um, Waving : less than 1.5um
NOTE :
Confirm the above specification put VTR horizontally and vertically with AJ-D92 and 94.
(Refer to figure 1)
TEST POINT Refer to [LISTA Adjustment Modes] on item 2. Table of Test Point.
VTR MODE PLAY
ADJ. MODE Select the mode according to adjusting Heads and mode.
Refer to [LISTA Adjustment Mode] on item 2. Table of Test Point.
ADJUST S1 and T1 Post Height
TOOL VFK1149 (Post Driver)
TAPE Type Tape
A, B, D, E, F, G, H, I, J NTSC : VFM3581KM (LISTA)
PAL : VFM3681KM (LISTA)
C NTSC : VFM3581KL (LISTA)
PAL : VFM3681KL (LISTA)
Figure 1
(b) Place Vertically(a) Place Horizontally
Set the Reel is upper side
CYLINDER