3-2
(Removal)
1. Remove the T1 Guide and Cleaning Arm Unit.
(Please refer to item “1-2. Cleaning Arm Unit
Replacement”)
Figure 1-1-1
2. Unscrew the screw (B) which fix the cable (B) as
shown in Figure 1-1-2.
3. Remove the flexible cable which connected to
connector (A) on the P.C.Board (B) as shown in
1-1-1.
4. Unscrew the 3 screws which have spring from the
Cylinder Unit as shown as Figure 1-1-1, then
remove the Cylinder Unit without touching any
mechanical parts as shown in Figure 1-1-2.
Figure 1-1-2
NOTE:
Never touch the cylinder by finger directly, when pull
out the Cylinder Unit.
(Installation)
1. Install the new Cylinder Unit according to the
opposite procedures to removing.
Figure 1-1-3
NOTE:
When installing the Cylinder Unit, the pin on Mech.
Chassis should match hole of Cylinder Unit as shown
in Figure 1-1-3.
2. After installing the T1 Guide, T1 Guide Position
Adjustment should be performed.
(Please refer to item “1-2. Cleaning Arm Unit
Replacement” and “1-3. T1 Guide Position
Adjustment”)
1-2. Cleaning Arm Unit
Replacement
(Removal)
1. Unscrew the 2 screws (A) and remove the T1
Guide as shown in Figure 1-2.
2. Widen the tip of the cleaner arm, lift up the
cleaning arm unit and remove the spring and
washer.
(Installation)
1. Install the spring and washer.