2. Cleaning Arm Unit insert temporary to T2 Arm
Unit. Install the spring to between Cleaner Base
Plate and Cleaning Arm Unit, and insert perfectly
Cleaner Arm Unit to T2 Arm Unit.
3. Rotate the cylinder by hand in the pressing the
core of the Cleaner Solenoid, and confirm that the
Cleaner Roller rotate.
4. Install the T1 Guide.
5. After install the T1 Guide, please perform the
item 1-3. T1 Guide Position Adjustment.
Figure 1-2
1-3. T1 Guide Position Adjustment
1. Place the unit to loading condition without the
tape.
NOTE :
Please refer to item 4.No Tape Loading Procedure
on Section 2. And refer to the item No tape loading
procedure on the service manual, if the model does
not mentioned at Classified list.
2. Observe the clearance (B) between T1 Guide and
T1 post as shown in Figure 1-3, and make sure
that it is within 0.2mm to 0.5mm.
3. If not, loosen the 2 screws (A) and adjust the
position of the T1 Guide moves to direction of
arrow (G ←→ G) so that the clearance (B) is
within specification. And tighten the 2 screws (A).