2-9
2-7. AJ-D90, AJ-D900, AJ-D910WA, AJ-PD900
<Table of Test Point>
Name AJ-D90, AJ-D900, AJ-D910WA, AJ-PD900
[ Reel Torque Adjustment ]
S-Side Reel Voltage SERVO : TP301
Adjust Point SERVO : VR502
T-Side Reel Voltage SERVO : TP302
Adjust Point SERVO : VR501
GND SERVO : TG300
[ Tension Arm Adjustment ]
TENSION SERVO : TP402
TENSION OFFSET SERVO : VR402
TENSION GAIN SERVO : VR401
[ Photo Sensor Voltage Adjustment ]
S-Side Sensor Voltage SERVO : TP503
Adjust Point SERVO : VR503
T-Side Sensor Voltage SERVO : TP504
Adjust Point SERVO : VR504
[ Tape Pass, A/C Head Adjustment ]
R/P-ENV L
PB-ENV L RF : CONNECTOR P4
R/P-HSW L (Distributed by BER Counter Tool.)
PB-HSW L
R/P-ENV R
PB-ENV R RF : CONNECTOR P5
R/P-HSW R (Distributed by BER Counter Tool.)
PB-HSW R
CUE LCD : TP505
LIVE-CTL SERVO : TP107
[ LISTA Adjustment ]
ATF ERR SERVO : TP601
TRG (R/P-HSW) SERVO : TP113
GND SERVO : TG300
ATF GAIN EVR
<How to set the Reel Adjustment Mode>
Adjustment Mode
Adjustment Name Mode Name Mode Change Procedure
Reel Torque Adjustment Reel Adjustment Mode (1) Short the TP505 and TP116 with power OFF.
(2) Turn ON the power and playback.
<how to set the LISTA Adjustment Mode>
Adjustment Mode
Mode Name Format Select
(LISTA Software)
TRG Connection
Sensitivity Adj.
(R/P)
“RP GAIN ED”
50M mode
(1) Short the TP902 and TP116 with power OFF.
(2) Turn ON the power and playback.
Linearity Adj. “RP LINEAR ED” (1) Short the TP902,TP116 and TP101 with power
OFF.
(2) Turn ON the power and playback.
Sensitivity Adj. (R/P)
25M compatible
“RP GAINDP”
25M mode
(1) Short the TP902 and TP116 with power OFF.
(2) Turn ON the power and playback.
Linearity Adjustment
25M compatible
“RP LINEAR DP” (1) Short the TP902,TP116 and TP101 with power
OFF.
(2) Turn ON the power and playback.
Pin PositionConnector
5 : HID RP L
6 : D GND
7 : RP ENV L
8 : PB ENV L
9 : A GND
5 : HID RP R
6 : D GND
7 : RP ENV R
8 : PB ENV R
9 : A GND
P4
P5
PAL
SW setting for Format Select
(SERVO PCB)
NTSC
OFF
ON
OFF
OFF
SW901 1
2
NOTE