3-14
1-18. Tension Arm Unit
Replacement
(Removal)
1. Remove the Cut Washer (A) and hang off the
Tension Regulator Spring, and then remove the
Tension Arm Unit as shown in Figure 1-18.
(Installation)
1. Install the new Tension Arm Unit follow the
removal steps in reveres order.
2. After installation, Tension Arm Adjustment should
be performed the following steps.
Figure 1-18
<Tension Arm Adjustment Flow Chart>
START
3-3. Tension Arm Offset Voltage Adjustment
3-5. Tension Arm PLAY Voltage Adjustment
3-4. Tension Arm Neutral Position Adjustment
3-6. Tension Arm REV Voltage
Confirmation
NG
3-6. Tension Arm Tension Regulator
Spring Adjustment
3-7. REV Tension Confirmation
& Screw Lock
NG
END

Table of Contents

Other manuals for Panasonic AJ-D230H