2-10
2-8. AJ-D92, AJ-D94, AJ-D95DC
<Table of Test Point>
Correspondence Model
Name AJ-D95DC AJ-D92, AJ-D94
[ Tension Arm Adjustment ]
TENSION RF : TP11 RF : TP1
TENSION OFFSET “A05 : TENSION OFST”
(Service Menu)
ß
TENSION GAIN AV SYS : VR1103 AV SYS : VR1101
[ Photo Sensor Voltage Adjustment ]
S and T Sensor Voltage “I02 : S PHOTO / T PHOTO”
(Display on the Service Menu)
ß
S-side Adjustment Point AV SYS : VR1102 ß
T-side Adjustment Point AV SYS : VR1101 AV SYS : VR1103
[ Tape Pass, A/C Head Adjustment ]
R/P-ENV L RF : TP401 ß
PB-ENV L (R/P or PB ENV Change on the Service Menu)
R/P-ENV R RF : TP501 ß
PB-ENV R (R/P or PB ENV Change on the Service Menu)
R/P-HSW L RF : TP903 ß
PB-HSW L RF : TP905 ß
LIVE-CTL RF : TP12 RF : TP2
CUE AUDIO : TP40501 AUDIO : TP102
[ LISTA Adjustment ]
ATF ERR RF : TP13 RF : TP3
TRG R/P-HSW L RF : TP903 ß
PB-HSW L RF : TP905 ß
GND RF : TG901 ß
ATF GAIN Select the EVR on the Service Menu.
(Refer to below table <LISTA Adjustment Mode>)
<A/C Head Adjustment Mode>
Adjustment Name Format Select Adjustment Mode (Select on the Service Menu)
Azimuth, X Value Adj. 25M Select the item “A13 : RP LIN 25M”
50M Select the item “A09 : RP LIN 50M”
<LISTA Adjustment Mode>
Adjustment Mode
Adjustment Name Format Select
(LISTA Software) Service Menu Item TRG Connection
Sens. Adjustment (R/P Head) “A08 : RP GAIN 50M” R/P-HSW L
Linearity Adjustment 50M mode “A09 : RP LIN 50M” R/P-HSW L
Sens. Adjustment (PB Head) “A10 : PB GAIN 50M” PB-HSW L
Sens. Adj. (R/P Head) 25M compatible “A12 : RP GAIN 25M” R/P-HSW L
Linearity Adjustment 25M compatible 25M mode “A13 : RP LIN 25M” R/P-HSW L
Sens. Adj. (PB Head) 25M compatible “A14 : PB GAIN 25M” PB-HSW L