2-46
3-32. LISTA Sensitivity Adjustment and Sensitivity Detection
ATF ERR
TEST POINT HSW
GND
Refer to item “2. Table of Test Point” and [LISTA Adjustment Mode] on “Table of
Test Point”.
VTR MODE PLAY
ADJ. MODE Select the mode according to adjusting Heads and adjustment mode.
Refer to [LISTA Adjustment Mode] on “Table of Test Point”.
ADJUST
(ATF GAIN)
Select the mode according to adjusting Heads and adjustment mode.
Refer to [LISTA Adjustment Mode] on “Table of Test Point”.
TAPE Type Tape
A, D, J NTSC : VFM3581KM (LISTA), PAL : VFM3681KM (LISTA)
VFM3000EDS (DV LISTA : When use the DV compatible mode Adj..)
B, E, F, G, H, I NTSC : VFM3581KM (LISTA), PAL : VFM3681KM (LISTA)
C NTSC : VFM3581KL (LISTA), PAL : VFM3681KL (LISTA)
<Classified list for Sensitivity Adjustment>
Type Models
A AJ-D440, AJ-D450, AJ-D640, AJ-D650, AJ-D750, AJ-D850
B AJ-D400, AJ-D610, AJ-D700, AJ-D700A, AJ-D800, AJ-D800A, AJ-D810, AJ-D810A
C AJ-D200, AJ-D210, AJ-D215
D AJ-LT75, AJ-LT85
E AJ-D220, AJ-D230, AJ-D230, AJ-D230H
F AJ-D780, AJ-DE77
G AJ-D950, AJ-D950A
H AJ-D90, AJ-D900W, AJ-D900WA, AJ-D910WA, AJ-PD900W, AJ-PD900WA
I AJ-D92, AJ-D94, AJ-D95DC
J AJ-D940
<Specification of confirmation and Adjustment according to Models>
Adjustment Heads and Sensitivity Value (mV/µm)
Type Normal (25M Model→25M, 50M Model→50M) 25M Compatible (50M) DV Compatible
R/P
Head
PB (L)
Head
PB (R)
Head
DVL
Head
R/P
Head
PB
Head
R/P
Head
DVR
Head
A, D 150 ± 15 150 ± 15 ----- ----- ----- ----- 130 ± 30 -----
B, C 100 ± 10 ----- ----- ----- ----- ----- ----- -----
E, F 150 ± 15 ----- ----- ----- ----- ----- ----- -----
G, I 150 ± 15 150 ± 15 ----- ----- 150 ± 15 150 ± 15 ----- -----
H 100 ± 10 ----- ----- ----- 100 ± 10 ----- ----- -----
J ----- 100 ± 10 150 ± 15 150 ± 15 ----- ----- ----- 200 ± 20