3-21
1-24. Cleaner Solenoid
Replacement & Adjustment
<CHART B>
Model Type TYPE A TYPE B TYPE C,D
Connector (A) P11 P2011 P618
P.C.Board (B) MECH
I/F
SERVO SERVO
(Removal)
1. Disconnect the connector (A) on the P.C.Board
(B). (Refer to above charts.)
2. Unscrew the 2 screws (A) and remove the
Cleaner Solenoid Unit as shown in Figure 1-24.
3. Unscrew the 2 screws (B) and remove the
Cleaner Solenoid as shown in Figure 1-24.
(Installation)
1. Install the new Cleaner Solenoid follow the
removal steps in reverse order.
2. After installation, execute the Cleaner Solenoid
Position adjustment.
Figure 1-24-1
1-24-1. Cleaner Solenoid Position
Adjustment
<Tools required>
Eccentric Driver (VFK0357)
1. Press the iron core of Cleaner Solenoid.
2. Observe the clearance (D) between Cleaning
Arm Unit and Cleaner Base Plate as shown in
Figure 1-24-2. And make sure that it is within 0.5
to 0.7mm.
3. If not, loosen the 2 screws (A) and adjust the
position of Cleaner Solenoid Unit by moving
arrow direction (C ←→ C) using the Eccentric
drive so that the clearance (D) is within
specification. And tighten the 2 screws.
4. After adjustment, confirm that as follow.
5. Press the iron core of Cleaner Solenoid and
released it, then the Cleaning Roller is return to
original position.
6. Press the iron core of the Cleaner Solenoid and
confirm that the Cleaner Roller is rotated, when
the Cylinder is rotated by hand.