2-49
Sensitivity Adjustment (In case of type C Models)
1. Connect the each clips to LISTA cable to test points.
2. Set the adjustment mode according to adjustment heads.
(Refer to [LISTA Adjustment Modes] of the Table of Test Point.)
3. Playback the LISTA Alignment Tape.
4. Select the item <6> ATF Error Signal Monitor on the LISTA main menu, and press the SPACE key for
execute the RS232C Connector Check. Normally the message RS232C CONNECTION COMPLETE!!! and
ATF GAIN value appeared on screen. After finish the Connection check, press the 0 key for download the
adjustment value of ATF GAIN. Next, press the Enter key and displayed real time sensitivity data.
5. The waveform as shown below figure appeared on the screen, press arrow keys on the keyboard of the PC so
that the Sensitivity. Value on the upper right corner of the screen is within specification.
Information 1 : Press the or key : The value changes by 1 step.
Press the or key : The value changes by 10 step.
After corrected the data, the screen is disappeared momentary during the calculating on
LISTA software.
Information 2 : The data 85 appear on the screen before adjustment, but this value is not VTRs value.
This value is equal to VTRs value after transmit the data once.
6. After finish this adjustment, press the ESC key to return to the main menu.
Adjust within specification